Supported Makes & Equipment Types
We repair control cards and power boards across all injection moulding machinery systems:
- Techmation Control Systems: AK668, AK580, Q8, Q9, OP5000, OP5200 motherboard and I/O cards
- Hot Runner Temperature Controllers (HRTC): Multi-zone PID temperature cards, solid-state relay (SSR) driver modules
- Mould Temperature Controllers (MTC): Thermocouple sensing circuits, pump and heater control PCBs
- Rexroth & Moog Proportional Cards: VT series amplifier cards, linear transducer feedback cards, pressure control cards
- Haitian, Toshiba, Ferromatik Milacron & L&T: Power supply cards, mould clamp safety logic cards
Common Faults & Micro-Diagnostic Solutions
| Failure Symptom | Circuit Defect | Component Fix |
|---|---|---|
| Zone Temperature Runaway / Overheat | Punctured Triac / Solid State Relay (SSR) driver channel on HRTC card. | Replace power triacs, test opto-triac gate trigger isolation. |
| Proportional Valve Pressure Fluctuation | Operational amplifier drift, dried filter capacitors in Rexroth card. | Replace precision current-loop op-amps, calibrate 0–10V / 4–20mA outputs. |
| Clamping / Injection Axis Position Error | Failed linear scale optical encoder buffer IC, corrupted 5V reference. | Replace line receiver chips, restore stable 5.00V reference rail. |
| Techmation Dead / Communication Error | SMPS rail voltage drop, burned RS-485 communication line chip. | Rebuild auxiliary SMPS power section, replace transceiver ICs. |
Our Bench Repair & Rig Testing Procedure
- Thermal Camera Heat Signature Analysis: Identifying hot spots, leaky SMD capacitors, and degraded power regulators under bench DC power.
- Component-Level Replacement: Replacing burned power transistors, optocouplers, PID controller chips, and electrolytic capacitors.
- Signal Simulator Validation: Simulating thermocouple J/K-type inputs, linear position transducer feedback, and proportional valve coil currents on the bench.
Injection moulding factory me jab HRTC temperature card ya Techmation board kharab hota hai, toh machine band pad jaati hai. Hum Jhajjar lab me cards ke triac, op-amp aur power ICs ko replace karke simulate karte hain. Manesar, Bawana aur Narela ke plastics units ko 24-48 hours me repair service dete hain.
Frequently Asked Questions
Can you repair multi-zone HRTC hot runner temperature controller cards?
Yes. We repair blown triac outputs, thermocouple sensor drift, and PID controller chips across all 4-zone to 24-zone systems.
How do you test Rexroth proportional amplifier cards?
We test proportional pressure and flow cards using electronic load simulators that measure coil current stability across the full 0–10V control command curve.