Supported VFD & Servo Drive Brands
We provide independent bench repairs for all global industrial inverter and servo controller brands used in manufacturing, textile, plastics, packaging, and CNC machinery:
- Danfoss: VLT AutomationDrive FC301 / FC302, VLT 2800, Aqua Drive FC202, HVAC Drive FC102, Micro Drive FC51
- Siemens: Sinamics G120, G120C, Micromaster 420 / 440, Simovert Masterdrives, Sinamics S120 servo drives
- ABB: ACS355, ACS550, ACS580, ACS800, ACS880 heavy-duty industrial inverters
- Delta: VFD-M, VFD-B, VFD-E, MS300, CP2000, ASDA-A2 / ASDA-B2 servo drives
- Schneider Electric: Altivar ATV312, ATV610, ATV71, ATV630, ATV930 process drives
- Yaskawa: A1000, V1000, GA700, J1000, Sigma-5 and Sigma-7 AC servo pack drives
- Allen-Bradley: PowerFlex 525, PowerFlex 40, PowerFlex 753 / 755, Kinetix servo drives
- Fuji Electric, Mitsubishi, Omron & Inovance: Frenic-Mini/Multi, FR-D700 / FR-A800, 3G3MX2, MD series
Common VFD Faults & Error Codes We Fix
Factory environments subject AC drives to heavy thermal cycles, voltage surges, conductive carbon dust, and phase imbalances. Our component-level diagnostics target the exact root causes of critical trips:
| Fault Code / Symptom | Underlying Root Cause | Component-Level Repair Solution |
|---|---|---|
| Overcurrent (OC / F0001 / AL01) | Punctured IGBT junction, shorted output phase, gate driver diode leakage. | Replace IGBT bridge, rebuild 6-channel gate drive resistors and optocouplers. |
| Overvoltage (OV / DC Bus High) | Failed braking chopper transistor, defective DC bus voltage divider sensing circuit. | Replace dynamic braking IGBT, calibrate high-precision voltage sensing op-amps. |
| Undervoltage (UV / Phase Loss) | Input bridge rectifier diode degradation, dry DC capacitor bank, open pre-charge relay. | Replace 3-phase input rectifier module, test ESR of electrolytic capacitor bank. |
| Ground / Earth Fault (GF / EF) | Current sensor (Hall effect sensor) drift, insulation breakdown on output traces. | Re-calibrate or replace Hall current sensors, apply conformal insulating coating. |
| No Display / Dead Power Supply | Blown primary SMPS switching IC (TOP/VIPer), shorted auxiliary transformer winding. | Rebuild 24V/15V/5V SMPS control circuit, replace secondary filter capacitors. |
Our 4-Stage Precision VFD Repair Protocol
- Cold Circuit Safety & Static Diagnostic: Comprehensive diode check on 3-phase input rectifier bridge and 6-pulse IGBT inverter stage. DC bus impedance analysis to prevent secondary short circuits upon power-up.
- Micro-Soldering & Component Replacement: High-temperature vacuum desoldering of damaged power modules. Replacement with OEM-grade IGBT modules, matched gate resistors, and isolated gate drivers (HCPL/TLP optocouplers).
- Gate Waveform Balancing on Oscilloscope: Verification of symmetric PWM square waves across all upper and lower gate channels before applying high voltage to the DC link.
- Dynamic Motor Load Rig Testing: Every drive is tested under continuous mechanical load coupled to our lab test motor. Current draw, thermal dissipation, ramp-up stability, and reverse torque are verified and documented.
Jab aapka VFD drive trip hota hai ya Overcurrent (OC), Overvoltage (OV), ya Dead Display dikhata hai, toh naya drive khareedne ki zaroorat nahi hai. Hum Jhajjar lab me drive ko kholkar multimeter aur oscilloscope par test karte hain. Blown IGBT module, gate driver circuit, aur DC bus capacitors ko replace karke dynamic motor load par chala kar test karte hain. 1 month ki complete warranty milti hai aur aapke 60% se 70% paise bachte hain.
Frequently Asked Questions
Can a blown IGBT module in a VFD be repaired without replacing the whole drive?
Yes. We desolder the damaged module, rebuild the gate driver resistors and isolation chips, and install a brand-new, thermally balanced power module. The drive operates with original factory performance at a fraction of the cost.
How do you test large horsepower drives?
We test drives up to 500 HP using our dynamic motor test rig, verifying current draw, thermal profile under infrared thermography, and regenerative braking chopper operation.
Do you offer pickup service from Gurgaon, Manesar, or Delhi?
Yes. For industrial customers in Gurugram, IMT Manesar, Rohtak, Bahadurgarh, and Delhi industrial belts, we offer direct pickup, drop-off, and zero visiting fee factory visits for critical line shutdowns.